Home > Products > Environment monitoring instruments > TH PM10/PM5/ PM2.5/PM1 separator/sampling cutter( new)
TH PM10/PM5/ PM2.5/PM1 separator/sampling cutter( new)
- 1000 Set / Sets per Month
- shenzhen
- T/T Credit Card
- LY2030 Intelligent medium-large -flow TSP sampler
- Y2050 Intelligent Air and TSP Comprehensive Sampler dual use Sampler
- ZR-3610 OLED constant current sampling air dust sampler
- EA119 smart dust sampling instrument
- CCZG2A Portable Individual dust sampler personal sampler
- 3012H Automatic Stack Dust/Gas Tester flue gas monitor
Product Details
Brand Name: | TH | Place of Origin: | Shaanxi, China | Model Number: | PM10 - PM5 - PM2.5 |
Product Description
TH PM10/PM5/ PM2.5/PM1 separator/sampling cutter( new)
The separator is designed according to the principle of shock, by PM5, PM10, PM2.5 levels, each level has a shock of orifice plate and impact separation collection plate. Tertiary impact separation collection plate structure is the same. Due to different size particles impact inertia, impact plate on the number of holes and pore diameter are different.
The separator is connected to my company's TH-150 series flow sampler , according to the different combinations can be used for scientific research institutes , universities, environmental protection departments in air TSP, PM10, PM5, PM2.5 ( total suspended particulates , respirable particulate matter and respiratory particulate matter ) sampling , to achieve a machine can function.
Technical characteristics of the various parts :
1. TSP sampling its performance to meet the national standard entrance requirement that
Entrance speed : 0.3m / s
Entrance width and height ratio : b / a = 0.625
2.PM10 separator :
da50 = 10.2μm
δg = da16/da50 = da50/da84 = 1.5
Meet the national standard GB6921-86 regarding particulates (PM10) sampler provides da50 = 10 ± 1μm and δg ≤ 1.5 requirements.
3. PM5 separator: da50 = 4.93μm
Compared with RMRC standard deviations of its trapping efficiency between 0.4-10.7 % , to meet the ISO report tolerance 15% requirement.
4. PM2.5 cutter : da50 = 2.47μm
And " typical particle size distribution " under "ideal sampler" mass concentration of particulate matter trapped predictive value relative deviation is 0.2%.
Meet the standards set forth in the Federal da50 = 2.5 ± 0.2μm, and the ideal sampler trap mass concentration of particulate matter relative deviation of ≤ 10% of the requirement.
Matching With sampler requirements:
1, the sample flow rate and accuracy : 100L/min ± 5%
2 , the sampling filters : Material : Fiberglass , Dimension : φ88
3 , connecting head size : φ18 × 2
Dear customer, We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history . Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science. Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system. If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba We firmly believe that science and technology is no boundaries Our mission is to make every effort to contribute to all humanity. |
Contact Us
- Lixian Instrument Scientific Co., Ltd.
- TH-BQX2 Professional portable gas dust sampler calibration device
- TH 880A smart dust sampling instrument
- JZH-103A Wireless dust sensor distributed particle sensor module
- TH 880D smart dust sampling instrument
- YM-O2A1 Flue gas oxygen analyzer
- ZR-3700A Portable Flue Gas Mercury Sampler sampling device instrument
- 3022D Flue Gas Comprehensive Analyzer
- YM3023 Flue gas analyzer
- 3022A Flue Gas comprehensive analyzer for SO2,NO,NO2,CO,H2S,CO2
- TH-990G Intelligent flue gas analyzer
- YM-20 Flue gas flow rate velocity meter monitor flowmeter
- TH-998 intelligent flue gas analyzer
- TH-2000S flue gas data acquisition instrument
- 3022B Flue Gas Comprehensive Analyzer
- TH-990F Automatic flue gas analyzer
- 3022 Portable Flue Gas Analyzer
- TH-2000G Automatic flue gas data acquisition instrument
- YM-50A Flue gas pressure measuring Transmitter
- TH-990F intelligent flue gas analyzer emission gas multiple gas monitor
- JLBG-129 multi-function Infrared Oil Content Analyzer
- EA117 Series Infrared gas or gas mixture Analyzers
- DZS-708 Multi-parameter water quality meter
- AT-B Hand-held CO2 detector
- ZR - 2031B fully automatic air microorganism sampler
Popular Searches
- xk3190 a9 weighing indicator
- copper/copper sulfate reference electrode
- glassy carbon electrode
- thermocouple head ksc
- adjustable thermostat 12v dc
- light weight steel
- bull eye level
- bulls eye level
- black mesa
- bloco
- Cast Iron Block
- class testing
- celtron load cell
- hf testing
- instrument accessoris
- jewelry scale calibration weights
Find Similar Products By Category
- Measurement & Analysis Instruments > Instrument Parts & Accessories
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-