Home > Products > Gas sensor > CH-D3 Miniature Size Combustible Gas Pellistor
CH-D3 Miniature Size Combustible Gas Pellistor
- 1000 Piece / Pieces per Month
- HK
- T/T PayPal
- BJ-93D Stand-combustible Gas Detector
- F2000TSM-CO2-S/L Carbon Dioxide (CO2) Gas Detector
- MF4000 Series Gas Flow Meters - MF4003/MF4008
- MF5600 Series Detachable Display Gas Flow Meters - MF5612/MF5619
- ETO-A1 Ethylene Oxide Sensor (ETO Sensor)
- SOH-A2 Sulfur Dioxide + Hydrogen Sulfide Sensor (SO2 + H2S Sensor)
Product Details
Brand Name: | Alphasense | Place of Origin: | United Kingdom | Model Number: | CH-D3 |
Usage: | Gas Sensor | Theory: | Other, Combustible Gas Sensor | Output: | Analog Sensor |
Product Description
CH-D3 Combustible Gas Pellistor Description
Alphasense flammable gas pellistors are available in two housing sizes: A for fixed installation applications and A or D for portable applications.
The innovative design of the Alphasense pellistor range provides high quality, low power (only 190mW) and excellent poison resistance. All pellistors are housed in certified flameproof chambers.
CH-D3, with the same good stability and high poison resistance of the CH-A3, is a unique miniature size, only 11.5mm height and 15mm diameter, complementing the existing Alphasense D sensor family.
The CH-D3 has full ATEX, IECEx, UL and CSA certification from -40°C to +50°C at 1.25W, optimising portable gas detector battery life with a shock-proof design.
CH-D3 Combustible Gas Pellistor PERFORMANCE | ||
Sensitivity | mV / % methane | 10 to 17 |
Response time | t90 from air to 50% LEL methane (s) | <12 |
Zero | mV in zero air | ±25 |
Range | % LEL methane | 0 to 100 |
Linearity | % methane when 5% non-linear | 6 |
CH-D3 Combustible Gas Pellistor ENVIRONMENTAL | ||
Sensitivity @ -20℃ | % sensitivity change, referenced to 20°C | 101.5 to 104.5 |
Sensitivity @ 50℃ | % sensitivity change, referenced to 20°C | 101.5 to 103 |
Zero @ -20℃ | % LEL change, referenced to 20°C | < ±2 |
Zero @ 50℃ | % LEL change, referenced to 20°C | <+0.5 to -1.5 |
Temperature Range | Certification to T4 | -40° to 50°C |
Humidity | 12% sensitivity loss from 0 % to 80 % rh (22°C) Typical zero increase % LEL from 0 to 80 %rh (22°C) | <1.0 |
Pressure | Sensitivity change from 0 to 75 kPa (gauge) | <3% |
CH-D3 Combustible Gas Pellistor INHIBITION/POISONING | ||
Chlorine | 12hrs 20ppm Cl 2 , 50% sensitivity loss, 2 day recovery | <10% loss |
Hydrogen Sulfide | 12hrs 40ppm H 2 S, 50% sensitivity loss, 2 day recovery | <50% loss |
HMDS | hrs until 50% activity loss @ 10ppm HMDS | <10 |
Optional H2S disposable filter can be ordered. Part no. ASF-2 | ||
CH-D3 Combustible Gas Pellistor ELECTRICAL | ||
Voltage | V (±0.2 V) | 3.0 |
Power consumption | mW | 190 |
Voltage sensitivity | % sensitivity change / 0.1V change | <3 |
CH-D3 Combustible Gas Pellistor KEY SPECIFICATIONS | ||
Weight | g | <10 |
Operating life | months until 75% original sensitivity (24 month warranted) | > 24 |
Sensitivity
Hydrocarbon/Gas | % Sensitivity relative to Methane | % LEL Sensitivity to Methane |
Hydrogen | 120 to 140 | 150 to 175 |
Ethane | 120 to 140 | 200 to 230 |
Propane | 140 to 170 | 330 to 400 |
Butane | 150 to 180 | 470 to 570 |
n-Pentane | 170 to 200 | 570 to 670 |
Hexane | 190 to 220 | 860 to 900 |
Heptane | 190 to 220 | 900 to 1050 |
Octane | 200 to 230 | 1000 to 1150 |
Nonane | 190 to 220 | 830 to 950 |
Acetylene | 140 to 160 | 280 to 320 |
Ethylene | 150 to 170 | 275 to 320 |
Isobutylene | 170 to 190 | 425 to 475 |
Contact Us
- Week technology ltd
- Contact nameCherry
- Phone86-0755-83289036-843
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South Shenzhen,Guangdong
- DSM501B Dust Sensor Module for Air Quality Monitor
- NO-B1 Nitric Oxide Sensor (NO Sensor)
- TC-BO3-3 Portable Combustible Gas Detector
- TOCON_BLUE4 GaP Blue Light Detector with Integrated Amplifier
- Y520-A 4-Electrode Conductivity Sensor
- AMT-pH PH Shallow Water Sensor with Integrated Electronic Device
- TSPC-30S1 Series ToughSonic 14 Ultrasonic Level & Distance Sensor
- MB1014 LV-ProxSonar-EZ1 High Performance Ultrasonic Rangefinder
- WQ101 Rugged Water Temperature Sensor
- IoLine-HPB IoLine High Performance pH Electrodes with Temperature Sensor
- TOCON_A4 UVA Photodetector with Integrated Amplifier
- SG01S-C18 UVC-only SiC Based UV Photodiode With Standard DVGW W294
- HCN-B1 Hydrogen Cyanide Sensor (HCN Sensor)
- PH3-BE Phosphine Sensor (PH3 Sensor)
- NO2-AE High Concentration Nitrogen Dioxide Sensor (NO2 Sensor)
- RESP_IRR_20 C 15x15 Respiratory Irritant Sensor 20 ppm C Package 110-902
- TOCON_E2 SiC Based UV-Index Photodetector with Integrated Amplifier
- SG01L-B18 UVB-only SiC Based UV Photodiode
- LLC200D3SH Optomax Digital Series Liquid Level Sensors
- MB1034 LV-ProxSonar-EZ3 High Performance Ultrasonic Rangefinder
- MTCS2601 Thermal Conductivity Sensor for Leak or Pressure Detection
- Clean CAP Plus Wireless Ultrasonic Fill-Level Sensor
- U14-REMOTE-232/485 ToughSonic REMOTE 14 Ultrasonic Water Level Sensor
- SONIC-ANEMO-DVC Ultrasonic Wind Speed Sensor
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Cherry
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-