Residual-current Operated Circuit Breaker-FTB3LE
- 10000 Piece / Pieces per Month
- T/T L/C D/P D/A
- 30 days
Product Details
Brand Name: | Foretech | Place of Origin: | China | Model Number: | FTB3LE |
Type: | Residual Current | Poles Number: | 4 |
Product Description
Mainly used in distribution lines of AC 50HZ, rated working voltage 230/400V, rated current not more than 63A. For overload & short circuit protection, also can be used for line non-frequent on-off operation and conversion, and It can also be used for conversion of infrequent operation between lines under normal conditions.The breaking ability can reach 12kA.
Model & Spec | FTB3LE | |
Technical parameters | ||
Standards | GB/T16917.1/IEC61009-1 | |
Certifications | CCC | |
Pole number | 1P+N, 2P, 3P, 3P+N, 4P | |
Rated current(A) | Type C | 6, 10, 16, 20, 25, 32, 40, 50, 63 |
Type D | 6, 10, 16, 20, 25, 32, 40 | |
Rated frequency(Hz) | 50 | |
Residual current characteristics (action type) | AC, A | |
Rated residual operating current lΔn (mA) | 30 (Type AC) 30, 50 (Type A) | |
Actuation time (ms) | <100 | |
Electrical characteristics | ||
Rated operating voltage Ue(V) | AC230 (1P+N, 2P) AC400 (3P, 3P+N, 4P) | |
Rated short-circuit breaking capacity lcn(kA) | 10 (40A-63A) 12 (6A-32A) | |
Rated impulse withstand voltage Uimp(kV) | 4 | |
Dielectric voltage, power frequency, 1min(kV) | 2 | |
Rated residual making capacity lΔm (kA) | 4.5 | |
Impact resistance (waveform 8/20) (kA) | 3 | |
Isolation function | Yes | |
Class of pollution | 2 | |
Use cat. (overvoltage category) | ll | |
Tripping type and characteristics | C-type curve (5ln~10ln) D-type curve (10ln~20ln) | |
Mechanical charateristics | ||
Contact status indicator | Green: open Red: close | |
Mechanical life (times) | 20000 | |
Electerical life (times) | 10000 | |
IP rate | IP40 (installed inside the distribution box) | |
Mechanical shock resistance (GB/T2423.5)(m/s²) | 150, continuously 11ms half-wave | |
Anti-vibration (GB/T2423.10) | 5g-20 cycles, frequency 5…150…5Hz (load 0.8ln) | |
Anti-humid heat (GB/T2423.4)(℃/RH) | 28 cycles (with 55/95…100) | |
Reference ambient temperature (℃) | 30 | |
Operating ambient temperature (℃) | -5~+40 | |
Storage temperature (℃) | -40~+70 | |
Installation characteristics | ||
Terminal type | U-shaped terminal, tunnel type | |
Max. wiring capacity | Conductor connection 25 mm², busbar inlet thickness 0.8-2 mm | |
Max. ultimate torque (N.m) | 5.1 (≤25A) 5.6 (>25A) | |
Tool | Pozi drive (double cross) | |
Installation | Installation on standard DIN rail (35mm) | |
Inlet method | Upper or lower | |
Outline dim. (mm) | 1P+N | 90*54*74.2 |
2P | 90*72*75.7 | |
3P | 90*100*75.7 | |
3P+N | 90*112.5*75.7 | |
4P | 90*130.5*75.7 |
/miniature-circuit-breaker-ftb3le.html
Contact Us
- LONGBON INTERNATIONAL INDUSTRY CO.,LTD
- Contact nameLinda
- Acrel smart circuit breaker 4PASCB1-63-C16-4P With local manual push rod, local electric control, remote control, etc
- Kraus&Naimer Conversion switchRotary/Reset switch Cam switch Motor switc CH10-A222- -600-FT2-F 758
- Acrel 1P smart circuit breaker ASCB1-63-C63-1P din rail installation widely used in Information and communicatomes,etc banks
- Acrel smart circuit breaker ASCB1-63-C32-1P din rail installation 1P widely used in Information and communicatomes,etc banks
- Acrel smart circuit breaker ASCB1-63-C32-1P din rail installation 1P widely used in Information and communicatomes,etc banks
- Acrel With local manual push rod, local electric control, remote control, timing control ASCB1-63-C16-2Pwidely use in banks etc
- Acrel ASCB1-63-C63-2P With local manual push rod, local electric control, remote control, timing control widely use in banks etc
- Acrel 4P smart circuit breaker ASCB1-63-C16-4P With local manual push rod, local electric control, remote control, etc
- Acrel din rail installation smart micro circuit breaker ASCB1-63-C63-4P Can be widely used in Commercial complex, etc.
- Acrel ASCB1-63-C32-2P smart micro circuit breaker din rail installation Can be widely used in Commercial complex, etc.
- Acrel Intelligent miniature circuit breaker ASCB1-63-C16-1P din rail installation Can be widely used in smart homes, etc
- Original Schneider circuit breaker LV429550
- Schneider XB4BD33 Push Button Switch
- Schneider XB4BD25 brand new Push Button Switch
- Schneider XB4BS8445 Push Button Switch
- Siemens Circuit Breaker 3RV2011-1EA10 Circuit Breakers
- Siemens Circuit Breaker 3VF7211-2BM60-0AA0 Circuit Breakers
- Siemens Circuit Breaker 3VF3111-1BS41-0AR2 Circuit Breakers
- Siemens Circuit Breaker 3VF3111-1BS41-0AB2 Circuit Breakers
- Siemens Circuit Breaker 3VF6211-1BM44-2HC2 Circuit Breakers
- Schneider Harmony XB4BP42 flush Push Button Switch
- Schneider XB4BP31 Pushing Buttons Push Button Switch
- Schneider XB4BA51 Pushing Buttons 22mm Push Button Switch
- Schneider XB4BA42 Pushing Buttons 22mm Push Button Switch
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Circuit Breakers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Linda
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-