Home > Products > Infrared Thermometer > Infrared Ear Thermometer ir thermometer no contact digital clinical thermometer -50 to 750C for industry Supplier's Choice
Infrared Ear Thermometer ir thermometer no contact digital clinical thermometer -50 to 750C for industry Supplier's Choice
- 30000 Piece / Pieces per Month
- shenzhen
- T/T Credit Card
Product Details
Place of Origin: | Guangdong, China | Brand Name: | OEM -- Customer-made | Model Number: | TL-IR750 |
Usage: | Industrial | Theory: | Infrared Thermometer | Accuracy: | +/-1.5 |
Temperature Range: | -50 to 750C |
Product Description
Infrared Ear Thermometer ir thermometer no contact digital clinical thermometer -50 to 750C for industry
This infrared thermometer is used for measuring the temperature of the object's surface, which is applicable for various hot, hazardous or hard-toreach objects without contact safely and quickly.
This unit consist of Optics, Temperature Sensor Signal amplifier,Processing circuit and LCD Display. The Optics collected the infrared energy emitted by object and focus onto the Sensor. Then the sensor
translates the energy into an electricity signal.
This signal will be turned out to be digital shown on the LCD after the signal amplifier and processing circuit.
Features:
1 Large Measurement Range
2 Laser On/Off Switch Function
3 LCD with White Backlight and Bar Graph Display
4 Celsius and Fahrenheit Switchable
5 High/Low Temperature Alarm Setting
6 Auto Power Off
7 Data Recording (30 Max) and Data Hold Function
8 Emissivity Adjustable
9 Room Temperature Measurement
10 MAX/MIN/AVG/DIF Reading Function
11 Low Battery Indicator
12 Stylish Mini Handheld Gun Design
Specifications:
Temperature Range: -50 to 750oC
Accuracy: ±1.5% or ±1.5oC
Resolution: 0.1oC or 0.1F
Repeatability: 1% of reading or 1oC
Response Time: 500mSec, 95% Response
Spectral Response: 8-14 um
Emissivity: 0.95 Preset (Adjustable)
Distance to Spot Size: 12:1
Operation Temperature: 0 to 50oC (32 to 122oF)
Operation Humidity: 10 to 90%RH
Storage Temperature: -10 to 60oC (14 to 140oF)
Storage Humidity: 10 to 75%RH
Size: 145*90*35mm
Weight: 120g (including average 9V battery)
Product description:
1.Laser output
2.Measuring button
3.LCD display
4.Product label
5.Rec button
6.Mode button
7.Laser/Backlight button
8.Max/Min/Avg/Dif button(↑)
9.oC/oF button(↓)
10.Battery cover
LCD display
1.Measuring indicator
2.HOLD symbol
3.Buzzer alarm symbol
4.Laser switch indicator
5.Low battery indicator
6.Low temperature limit alarm
7.High temperature limit alarm
8.Bargraph
9.Temperature units:oC,oF
10.Digtal readout
11.MaxMin/Avg/Dif reading mode incicator
12.Data recording display(Max 30 datas)
13.Emissivity(adjustable)
14.Room temperature measurement reading
Field of View
This infrared thermometer’s field of view is 12:1, meaning that if the meter is 12 inches from the target, the diameter of the object under test must be at least 1 inch. Other distances are shown below in the field of view diagram.
Operation:
1.Turning on and off your Meter
Press the Measuring button to turn on the meter,
The meter will auto power off after 7sec with any operation
2.Hold function
This instrument automatically enter hold mode without measuring
Under hold mode, current reading display will be freezed.
3.MAX/Min/Avg value measurement function
11.Press Max/Min/Avgbutton(↑) to choose Max reading,Min reading,Avg reading display mode
Max: When is this mode the meter will display the maximum value has reached
Min: When is this mode the meter will display the minimum value has reached
AVG: When is this mode the meter will display the average value has reached
DIF:When is this mode the meter will display the differential value of maximum value and minmum value has reached
4.Laser and Backlight function
a.Press Laser/Backlight button to turn on/off laser.
b.Press this button over 2sec to turn of/off backlight
5.Temperature units switch function
Press oC/oF button(↓) to switch the temperature units between Celsius and Fahrenheit
6.Datas recording function
Press Rec button to manual store any measuring datas (Max 30 datas).
7.Datas recall function
Press Rec button over 2sec to recall datas
*oC/oF button(↓); Max/Min/Avg button(↑)
8.Low and High temperature limit alarm setup
Press Mode button over 2sec to adjust alarm temperature
*Mode button(→);oC/oF button(↓) ; Max/Min/Avg button(↑)
9.Emissivity adjustable
Under Scan mode:press oC/oF button(↓) and Max/Min/Avg button(↑) to adjust the emissivity
Most (90% of typical applications) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cove the surface to be measured with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or painted surface.
Emissivity Values
Substance | Thermal emissivity | Substance | Thermal emissivity |
Asphalt | 0.90 to 0.98 | Cloth (black) | 0.98 |
Concrete | 0.94 | Human skin | 0.98 |
Cement | 0.96 | Lather | 0.75 to 0.80 |
Sand | 0.90 | Charcoal (powder) | 0.96 |
Earth | 0.92 to 0.96 | Lacquer | 0.80 to 0.95 |
Water | 0.92 to 0.96 | Lacquer (matt) | 0.97 |
Ice | 0.96 to 0.98 | Rubber (black) | 0.94 |
Snow | 0.83 | Plastic | 0.85 to 0.95 |
Glass | 0.90 to 0.95 | Timber | 0.90 |
Ceramic | 0.90 to 0.94 | Paper | 0.70 to 0.94 |
Marble | 0.94 | Chromium oxides | 0.81 |
Plaster | 0.80 to 0.90 | Copper oxides | 0.78 |
Mortar | 0.89 to 0.91 | Iron oxides | 0.78 to 0.82 |
Brick | 0.93 to 0.96 | Textiles | 0.90 |
SAFETY
1.Use extreme caution when the laser beam is turned on.
2.Do not let the beam enter your eye, another person’s eye or the eye of an animal.
3.Be careful no to let the beam on a reflective surface strike your eye.
4.Do not allow the laser light beam impinge on any gas which can explode.
Battery Replacement:
If the meter does not power on as usual or the low battery icon appears on the LCD display, please replace the batteries with a new 9V battery as soon as possible. The way to open the battery cover see below operation:
Dispose of the battery in an environmentally safe at a recycling point.
DO NOT DISPOSE OF IN YOUR BIN!
Trouble Shooting:
1. Power on but no display or the display disappears
a. Check the battery is in place with good contact to the pins and the correct way round.
b. Remove battery for one minute and re-install.
c. Replace the battery.
2. For all other issues please contact your supplier.
Our services:
1.Sample order/Mix order is available;
2.Sample charge is refundable !
3.If order quantity is big , we will provide you most competitive price !
4.OEM and ODM service is available.
5.Cheapest shipping cost could be provided!
Contact:
Pictures:
Contact Us
- Dongguan Xinrui Instrument Co., Ltd.
- Contact nameAndy shi
- Phone86-0769-82024125
- AddressNo,19,Banhujiujie Dongguan,Guangdong
- USA original BENTLY 3500/44-01-00
- Carel refrigeration thermostat PJEZY0H000 cold storage controller
- Carel refrigeration thermostat PJEZS2P010 cold storage controller
- Carel refrigeration thermostat PJEZS0H000 cold storage controller
- Carel refrigeration thermostat PJEZS00000 cold storage controller
- Carel refrigeration thermostat PJEZC0P000 cold storage controller
- Carel refrigeration thermostat PJEZC0H000 cold storage controller
- Carel refrigeration thermostat PJEZC00000 cold storage controller
- Carel multi-parallel refrigerator controller MX30M25H00 temperature controller MPX PRO
- 698 photovoltaic protocol converter photovoltaic inverter power generation electricity consumption information collection
- New York Inspiration Temperature Sensor, Model 025W39721-302
- Repair of the exhaust temperature probe of the new York temperature sensor 639A0151H01 compressor condensing unit
- USA original bently nevada 330171-00-08-10-02-00 330173-00-05-10-12-00 330172-16-42-10-01-00
- USA original bently nevada 330130-040-00-00 330130-085-00-05
- USA original bently nevada 330106-05-30-10-02-00 330106-05-30-15-02-CN 330130-035-00-CN
- USA original bently nevada 330104-00-04-10-02-00 330103-11-19-10-02-00 330106-05-30-05-02-CN
- USA original bently nevada 330104-00-04-10-02-CN
- USA original bently nevada 330104-00-03-05-02-00
- USA original bently nevada 330103-12-25-10-01-00 330103-13-23-05-02-00 330103-15-23-05-02-CN
- USA original bently nevada 330103-05-15-05-02-00 330103-05-13-10-02-00 330103-10-20-05-02-CN
- USA original bently nevada 330103-02-12-05-02-CN 330103-03-12-05-02-00 330103-05-10-10-02-05
- USA original bently nevada 330103-00-20-10-02-00 330103-01-07-05-02-00 330103-02-07-10-02-00
- USA original bently nevada 330103-00-15-05-01-00 330103-00-18-05-02-05 330103-00-16-10-01-00
- USA original bently nevada 330103-00-08-10-02-00 330103-00-10-05-01-00 330103-00-12-10-01-00 330103-00-14-05-02-00
Popular Searches
- phone logger
- recorder
- thermometer hygrometer
- Bath Thermometer Strip
- data measurement
- recorders
- Temperature Data Logger
- digital thermostat
- fan thermostat
- control thermostat
- temperature recorder
- temperature humidity data logger
- data recorder
- temperature humidity sensor
- Humidity Data Logger
- Usb Data Logger
Recommended Products
- Programmable Temperature And Humidity Testing Machine Climatic Aging Test Chamber Environmental Chamber
- Wholesale Temperature And Humidity Testing Chamber Climatic Test Chamber Environmental Test Equipment
- ESS Prismatic battery pack assembly machine cylindrical 32650 32140 21700 18650 Battery Module Pack machine
- ASTM D4060 TABER Abrasion Tester Textile Abrasion Test Equipment TABER Wear Testing Machine
- Rotary Taber Abrasion Tester Taber Abrasion Resistance Test Machine Leather Wear Resistance Testing Equipment
- Acrel three phase smart energy meter LED display 2DI2DO cut out 67*67mm AMC72-E4/KC Accuracy level 0.5
- Acrel Intelligent power collection and monitoring device AMC72L-E4/KC three phase LCD display 2DI2DO panel size 75*75mm
- Strong Mobility Portable Smart Lithium Battery Vertical Torque Wrench
- Nuclear Radiation Detector GM Geiger Counter, Sensitive Radiation Dosimeter Monitor Radioactive β Gamma X-ray CPM Level w/Alarm
- AITOP 5v3a6a10a20a30a50a60a100a Capacity Tester 8ch 5v100a Battery Capacity Tester battery charge discharge tester
- AITOP 32ch 64ch 5V60A30a20a10a Capacity Tester 8ch 5v100a Battery Capacity Tester battery charge discharge tester
- AITOP Capacity Tester 5V100A Battery Capacity Tester battery capacity charge discharge tester
Find Similar Products By Category
- Measurement & Analysis Instruments > Temperature Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy shi
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-